EHE
EHE N250k to N500k-TL
Procedure
•
If you make the cable yourself, connect the wires as shown in the diagram:
Terminal strip inside the first inverter Terminal strip inside the second inverter
Terminal Terminal
JX9 - A JX9 - A
JX9 - B JX9 - B
•
Wiring the remaining inverters in the same way.
•
Terminate the last inverter according to the inverter instructions.
•
Insert the terminal block connector into the Solar-Log™ RS485 socket.
Procedure
1. Connect the data cable to the blocks JX2 A and B on inverter 1.
2. Connect the data cable to the blocks JX2 A and B on inverter 2.
3. Connect the remaining inverters in the same way.
4. Terminate in the last inverter according to the manufacturer's instructions.
5. Close the inverter if no other inverters are to be connected.
6. Insert the terminal block connector into the Solar-Log™ RS485 socket.
Notes on inverter addresses
•
Recommendation: Continuous numbering starting with 1.
•
Settings: On the inverter operating display.
•
Procedure: Follow the manufacturer's documentation for the inverter.