Growatt
Growatt
Allocate communication address
•
Recommendation: Continuous numbering starting with 1.
•
Address range: 1 - 125
•
Setting: Using the inverter operating display
•
Procedure: Start according to the inverter's instructions
Note
When detecting inverters, there are two options for for Growatt in the initial configuration.
"Growatt old" and "Growatt Mod". For newer models and modules with the latest firmware
version version, please select "Growatt Mod", for models with older firmware versions se-
lect "Growatt old".
Inverters Firmware version
Sungold 1500TL/2000TL/3000TL/5000TL >= G.2.1 Modbus
Growatt 1500TL/2000TL/3000TL/4000TL/4400TL/5000TL >= G.2.1 Modbus
Growatt 2500MTL/3000MTL Modbus
Growatt 3600MTL/4200MTL/5000MTL >= S.2.1 Modbus
Growatt 3600MTL-10/4200MTL-10/5000MTL-10 Modbus
Growatt 2000HF/2500HF/3000HF Modbus
Growatt 10000UE/12000UE/18000UE/20000UE Modbus
Growatt 4000UE/5000UE/6000UE Modbus
Growatt 1500TL-US/2000TL-US/3000TL-US >= U.1.5 Modbus
Growatt 3600MTL-US/4200MTL-US/5000MTL-US >= U.1.5 Modbus
Growatt 2000HF-US/2500HF-US/3000HF-US Modbus
Growatt 8000TL-US/9000TL-US/10000TL-US/11000TL-US Modbus
Growatt 10000TL3-US/12000TL3-US/18000TL3-US/20000TL3-US Modbus