Solare-datensysteme Solar-Log Manual de usuario Pagina 211

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 311
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 210
211
Schüco
Schüco SGI series (RS485)
Connect the inverters to each other
•
Connect using a network cable (patch cable)
•
Where to connect: RJ45 sockets on the bottom of the inverter
Procedure
1. Open the unit cover on the bottom of the inverter.
2. Insert the RJ45 plug into any RJ45 socket on inverter 1.
3. Insert the other end of the wire into any RJ45 socket on inverter 2.
4. Connect the other inverters to each other in the same way.
5. Terminate in the last inverter.
Insert the IP20 terminal plug into a free RJ45 socket (not strictly required for cables up to 100 m long).
6. Close the unit cover on the bottom of the inverter.
Allocate communication address
•
Recommendation: Continuous numbering starting with 1.
•
Setting: Using the inverter operating display
•
Procedure: Start according to the inverter's instructions
Vista de pagina 210
1 2 ... 206 207 208 209 210 211 212 213 214 215 216 ... 310 311

Comentarios a estos manuales

Sin comentarios