Configuring connected devices
•
SAVE settings
18�5�2 Configuring power meters
A function needs to be assigned to power meters to configure them.
Possible functions for power meters:
•
Inverter mode
•
Consumption meter
•
Meter for the entire plant
•
Utility Meter (U)
•
Utility Meter (U+I)
•
Sub-consumer
Note
Several consumption meters can be defined for every plant. Their measurements are
added to the total consumption.
Note
A sub-consumption meter is a consumption meter whose consumption has already
been recorded by another meter. It is used to visualize the consumption from a par-
ticular appliance or group.
Procedure
•
Select Device
•
Select the desired operating mode from the Meter configuration section.
•
If needed, assign a plant group to this meter.
•
SAVE settings
18�5�3 Configuring sensors
Under sensors, the configuration only comprises of activating other sensors.
Procedure:
•
Use the Ambient Temperature and/or Wind button to activate the sensors
•
If needed, make assignments to the module field.
•
SAVE settings.