Notifications by LED (Solar-Log 200, 500 and 1000)
Faults
LED 1 LED 2 LED E LED P Meaning and possible remedy
quickly quickly off For 5 min. during initialization:
Error!
» Pull out power plug and plug
in again.
lit slow slow Failed to synchronize the time via
the Internet.
» Set the time manually.
» Check Internet connection.
off slow slow Congurationinvalidornotread-
able:
» Check interface.
» Check cable.
» Restarting.
lit Only with Fronius inverters:
No data communication!
» Wait for inverter feed-in
» Check the wiring.
quickly Plant has reported a fault.
slow If the P LED is blinking, this indi-
cates that the inverter is being
controlled (power reduction) by
the feed-in power management.