Solare-datensysteme Solar-Log Manual de usuario Pagina 90

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 242
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 89
90
Configuring connected devices
18�2 Defining Smart Home / Smart Energy switches
The switches that are to be used for the Smart Home / Smart Energy function - switching on appliances
in certain production scenarios - have to be defined and configured. A maximum of 10 switches is available.
Select the definition in the
Configuration | Devices | Definition menu. The switches used are defined
here. The next step is to detect these defined devices in the
Configuration | Devices | Detection menu.
The control logic for the defined switches can be programmed in the
Configuration | Special Functions |
Smart Home / Smart Energy
menu.
Switch configuration menu
In the section, the switches 1-10 can be selected and their hardware can be defined.
Procedure:
•
Select switch place
•
Enter the switch name (max. 16 characters)
•
Define the switch type
•
The following switch types are available:
•
Internal relay (only Solar-Log 1200 and 2000)
•
Allnet 3075/3076
•
Allnet 3000
•
Gude 1100/1101
•
Gude 1002
•
Allnet 3075/3076 V2
•
Allnet 3073
•
Solar-Log™ Smart Relay Box (The connection via RS485 cannot be combined with inverters con-
nected to the RS485 bus)
•
Gude 2301
•
Solar-Log Smart Relay Station 3x 3.5kW
•
Solar-Log Smart Relay Station 1x 3.5kW
•
Belkin WeMo Socket
•
Belkin WeMo Insight
•
Allnet 3075 V3
•
Select the corresponding switch type
•
Activate the switch
•
The IP address of the switch needs to be entered when the switch is to be controlled via an IP ad-
dress (all of the relays other than the internal relay and the Smart Relay Box).
The RS485 used needs to be selected for the Smart Relay Box.
•
There is a prompt for the RE485 connection and also the desired relay with the Smart Relay Box.
Enter the number of the relay (0-7) is this field.
•
The sub-address (1-4 for each relay) needs to be defined when using the Gude 1002 and Gude 2301
(4 Relay).
•
SAVE settings.
•
If several switches are to be used, repeat these steps for each switch.
Note
Refer to the manufacturer's manuals to configure the IP addresses for the IP sockets.