2.5 Starting Up at the Solar-Log™
By switching-on the Solar-Log™, it will provide power to the Sensor Box Professional Plus. Afterwards, the
Sensor Box Professional Plus must be congured to the free RS485-port:
Open the dialogue Conguration | Devices | Denition in the WEB menu of the Solar-Log™.
Please refer to the Installation Manual in chapter “Connecting accessories”, “Installation” and “Congu-
ring connected devices”.
Select „M&T Sensor“ as interface.
Carry out device detection.
The Sensor Box Professional Plus is integrated with the system in the same way as an inverter. The further
conguration could be handled with the Solar-Log™ web interface.
2.6 Technical Data
Sensor Box Professional Plus
Dimensions, weight W/H/D in mm: 145/85/40, 360 g
Housing
Powder-coated aluminum
Protection mode IP65
Operating temperature -20 °C to +70 °C
Power supply Via RS485 data cable from Solar-Log™ (10,5-28 V
DC
),
Supply Current Typical 10 mA
Communication Port RS485
Protocol
Solar-Log™, 9600 Baud, 8N1
Irradiance Irradiance : ± 5 % (0 W/m
2
to 1400 W/m
2
)
Cell-temperature: ± 1K (-20 °C to +70 °C) / ± 2 K (-40 °C to
+85 °C)
Installation with screws on the substructure
Connection cable
4 pole, 3 m (10 feet), weather and uv resistant (LiY(St) 11 Y (4
x 0,14)
prolongable up to 50 m (165 feet)
Conformity CE :DIN EN-61000-6-1:2007 and DIN EN-61000-6-3:2007